Comparison of Over-the-Head and Standard Lateral Cardiopulmonary Resuscitation: A Prospective Crossover Simulation Study


Koca Y., BOZAN Ö., Ferhatlar M. E., Doğruyol S., KALKAN A.

Journal of Emergency Medicine, cilt.87, ss.199-207, 2026 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 87
  • Basım Tarihi: 2026
  • Doi Numarası: 10.1016/j.jemermed.2026.05.005
  • Dergi Adı: Journal of Emergency Medicine
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, CINAHL, EMBASE, MEDLINE, Academic Search Ultimate (EBSCO)
  • Sayfa Sayıları: ss.199-207
  • Anahtar Kelimeler: cardiopulmonary resuscitation, chest compression, heart arrest, simulation training, emergency medicine
  • Sağlık Bilimleri Üniversitesi Adresli: Evet

Özet

Background High-quality cardiopulmonary resuscitation (CPR) is fundamental to survival. Standard training emphasizes the lateral position, but confined spaces (e.g., airplane aisles, ambulances, narrow hallways) often necessitate the over-the-head (OTH) technique. The effect of this position on compression biomechanics remains unclear. Study Objectives To compare OTH and standard lateral CPR techniques in a manikin simulation regarding the quality of chest compression and rescuer fatigue. Methods This prospective, crossover simulation study included 45 experienced health care professionals. Participants performed 2 min of continuous chest compressions in both lateral and OTH positions, separated by a 24-h washout period. Compression depth, rate, and fraction were recorded using a CPR feedback–capable defibrillator, with real-time audiovisual feedback disabled during data collection. Fatigue was assessed using a numeric rating scale. Results A total of 41 participants completed the protocol. The mean compression rate (121.7 vs. 120.5/min, p = 0.306) and mean depth (49.5 vs. 49.5 mm, p = 0.897) were similar between the OTH and lateral positions, indicating comparable average depth adequacy. However, reflecting lower consistency, the percentage of compressions within the target depth range (50–60 mm) was considerably lower in the OTH position (35.2% vs. 49.4%, p = 0.027). Self-reported fatigue scores did not differ considerably (2.5 vs. 2.8, p = 0.132). Conclusion Although OTH CPR achieved a similar average depth and rate to the lateral position, it resulted in a lower proportion of compressions within the optimal depth range. Therefore, OTH CPR seems to be a feasible situational alternative in confined environments when lateral access is limited. Dedicated training may be needed to optimize depth in the OTH position. © 2026 Elsevier Inc.