Comparison of polymerase chain reaction and conventional methods in detecting methicillin-resistant Staphylococcus aureus.


ADALETİ R., Nakipoglu Y., KARAHAN Z. C., Tasdemir C., Kaya F.

Journal of infection in developing countries, cilt.2, sa.1, ss.46-50, 2008 (Scopus)

Özet

Accurate and rapid detection of methicillin-resistant Staphylococcus aureus is very important in a clinical laboratory setting to avoid treatment failure. Conventional methods were compared against the gold standard polymerase chain reaction (PCR) technique to determine the best combination of the routine procedures. Methicillin resistance was investigated in 416 clinical Staphylococcus aureus isolates by PCR, oxacillin agar screening (OAS), oxacillin disk diffusion (ODD) and cefoxitin disk diffusion (CDD) methods. Two hundred and ten (51%) out of 416 S. aureus strains were found to be mecA-positive by PCR. Sensitivity and specificity of the ODD, CDD and OAS methods were detected as follows: 100% and 89%, 99.50% and 100%, and 99.50% and 100%, respectively. Combining the ODD and CDD methods could be a good choice for detecting methicillin resistance in S. aureus strains where mecA PCR cannot be performed.