Effects of Topical Ozone Application on Outcomes after Accelerated Corneal Collagen Cross-linking: An Experimental Study


Creative Commons License

ŞANAL DOĞAN A., Gurda C., Caliskan S., ÖNDER E., Kaymaz F., Bilgic E.

Journal of Ophthalmic and Vision Research, cilt.15, sa.3, ss.289-298, 2020 (ESCI, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 15 Sayı: 3
  • Basım Tarihi: 2020
  • Doi Numarası: 10.18502/jovr.v15i3.7447
  • Dergi Adı: Journal of Ophthalmic and Vision Research
  • Derginin Tarandığı İndeksler: Emerging Sources Citation Index (ESCI), Scopus, CINAHL, International Bibliography of Art, Directory of Open Access Journals
  • Sayfa Sayıları: ss.289-298
  • Anahtar Kelimeler: Ozone, Corneal Collagen Cross-linking, Corneal Confocal Microscopy, Corneal Oxygen, Experimental
  • Açık Arşiv Koleksiyonu: AVESİS Açık Erişim Koleksiyonu
  • Sağlık Bilimleri Üniversitesi Adresli: Evet

Özet

Purpose: Ozone is a trioxygen molecule that spontaneously degrades into oxygen and oxygen free radicals. This study was designed to assess the effects of topical ozone application on outcomes after corneal collagen cross-linking (CXL). Methods: Enucleated fresh cadaver yearling sheep eyes (n = 28) were divided into five groups: control (C, n = 6), sham (S, n = 6), ozone only (Z, n = 6), CXL only (X, n = 5), and Ozone + CXL (ZX, n = 5). In all groups, except C, the epithelial layer was removed. In group Z, 20 μg/mL liquid ozone was topically applied. In group X, CXL was performed in the accelerated pulse mode. In group ZX, both CXL and ozone were applied. Post-interventional oxygen levels were determined and corneal confocal microscopy and optical coherence tomography were performed. Corneas were evaluated using light and electron microscopy. Results: Pre-interventional central corneal thickness (CCT) was highest in the control group and considerably similar in the remaining groups (P = 0.006). Pre-and post-interventional CCT were significantly different in the ozonated groups (Z and ZX) (P = 0.028; P = 0.043). Demarcation line depths were similar in groups Z, X, and ZX (P = 0.343). Increased stromal tissue reflectivity was observed in groups Z, X, and ZX. Oxygen levels were higher in the ozonated groups (Z and ZX) (P = 0.006), and caspase activity was higher in the CXL groups (X and ZX) (P = 0.028) as compared to the other groups. Group ZX showed tighter, more regular, and parallel fibrils. Conclusion: Ozone increases corneal stromal oxygenation which can probably augment the effect of CXL. Future studies should investigate the safety and feasibility of ozone application during CXL.