Efficacy of hyperbaric oxygen therapy on central corneal thickness, intraocular pressure, and nerve fiber layer in patients with type 2 diabetes: A prospective cohort study


Creative Commons License

KALDIRIM H., Atalay K., Ceylan B., YAZGAN AKPOLAT S.

Korean Journal of Ophthalmology, cilt.35, sa.1, ss.1-9, 2021 (Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 35 Sayı: 1
  • Basım Tarihi: 2021
  • Doi Numarası: 10.3341/kjo.2020.0076
  • Dergi Adı: Korean Journal of Ophthalmology
  • Derginin Tarandığı İndeksler: Scopus, MEDLINE
  • Sayfa Sayıları: ss.1-9
  • Anahtar Kelimeler: Central corneal thickness, Hyperbaric oxygenation, Intraocular pressure, Retinal nerve fiber layer, Type 2 diabetes mellitus
  • Açık Arşiv Koleksiyonu: AVESİS Açık Erişim Koleksiyonu
  • Sağlık Bilimleri Üniversitesi Adresli: Evet

Özet

Purpose: To evaluate the effect of hyperbaric oxygen therapy (HBOT) on central corneal thickness (CCT), intraocular pressure (IOP), and the retinal nerve fiber layer (RNFL) thickness in patients with type 2 diabetes mellitus. Methods: This prospective non-randomized cohort study consisted of type 2 diabetes mellitus patients who received 30 sessions of HBOT for diabetic foot ulcer. The CCT, IOP, and RNFL measured at baseline, after the 10th session of HBOT, after the 20th session of HBOT, after the 30th session of HBOT, and after the 3 months of the last session of HBOT. We gained the superior-nasal, superior-temporal, inferior-nasal, inferior-temporal, nasal and temporal quadrant RNFL values with a spectral-domain optical coharence tomography. Results: Forty-six eyes of 46 patients included in the study. During the study period, a statistically significant increase in mean IOP values compared to baseline was observed (p < 0.001). We found no significant changes at CCT and all quadrants of RNFL values during HBOT and after 3 months of the treatment (p > 0.05). During the study period, the IOP levels increased over 21 mmHg (between 22 and 28 mmHg) in seven eyes (15.2%). The mean hemoglobin A1c values of these patients with IOP >21 mmHg were 8.2 ± 0.9 mg/dL, and there was significant differences compared with those of patients with IOP values ≤21 mmHg (7.4 ± 2.8 mg/dL) (p = 0.001). Conclusions: HBOT increase IOP in type 2 diabetic patients especially in ones with impaired blood glucose regulation. However, it does not cause any changes in CCT and RNFL. As diabetic retinopathy and diabetic foot ulcer are in common pathologies, thus this brief report concludes a need for further studies with longer follow-up periods to explore the potential interaction of HBOT on CCT, IOP, and RNFL.