LigaSure Precise® use in thyroid operations: A comparison with the conventional method
European Surgery - Acta Chirurgica Austriaca, cilt.39, sa.1, ss.54-56, 2007 (Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 39 Sayı: 1
- Basım Tarihi: 2007
- Doi Numarası: 10.1007/s10353-006-0300-6
- Dergi Adı: European Surgery - Acta Chirurgica Austriaca
- Derginin Tarandığı İndeksler: Scopus
- Sayfa Sayıları: ss.54-56
- Anahtar Kelimeler: LigaSure (R) thyroid surgery, surgical complications
- Sağlık Bilimleri Üniversitesi Adresli: Hayır
Özet
Background: Most of the complications of thyroid operations are related to ligation and coagulation procedures. LigaSure® is an alternative method for vessel sealing and ligation and may decrease operative complications. This study analyzed the effect of LigaSure® use on duration of operation and on complication occurrence, compared to that of conventional methods. Methods: Forty patients with multinodular goiter were included. They were divided into two groups; the first operated with conventional methods and the second with LigaSure®. The groups were compared statistically for post-operative complications, hospital stay and operation time. Results: LigaSure® shortened the operation time significantly (approximately 13 min shorter) compared to conventional group and there was no significant difference on complication and hospital stay. Conclusions: LigaSure® can be safely used for thyroidectomy. It is considered to be a major tool in thyroid surgery. © Springer-Verlag 2007.