Performance of a photoscreener in detecting accommodation spasm
Clinical and Experimental Optometry, cilt.105, sa.8, ss.817-821, 2022 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 105 Sayı: 8
- Basım Tarihi: 2022
- Doi Numarası: 10.1080/08164622.2021.1989973
- Dergi Adı: Clinical and Experimental Optometry
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, CINAHL, EMBASE, MEDLINE
- Sayfa Sayıları: ss.817-821
- Anahtar Kelimeler: Accommodative spasm, photoscreeners, pseudo-myopia
- Sağlık Bilimleri Üniversitesi Adresli: Evet
Özet
Clinical Relevance: For a correct spectacle prescription, accommodation spasm should not be overlooked in the measurements made using an autorefractometer. Although this can be easily understood with cycloplegia, it is not practical. Therefore, investigating practical methods that can predict excess accommodation will be useful in clinical practice. Background: To evaluate the performance of a photoscreener in detecting pseudo-myopia due to accommodation spasm and whether it eliminates the need for cycloplegia. Methods: Study was conducted in Van Training and Research Hospital. The manifest refraction of the patients was measured using an by an autorefractometer followed by a photoscreener before cycloplegia. Cycloplegic refraction errors were detected using an autorefractometer. Patients with pseudo-myopia due to accommodation spasm were diagnosed by observing a significant hyperopic shift in cycloplegic autorefractometer values compared to the non-cycloplegic values and were included in study. Cycloplegic autorefractometer and non-cycloplegic photoscreener measurements were compared. Results: The mean non-cycloplegic autorefractometer values were as follows: -−6.34 ± 1.29D, −0.42 ± 0.58D, and −6.55 ± 1.36D for spherical, cylindrical, and spherical equivalents, respectively. These values were 0.23 ± 0.63D, −0.21 ± 0.41D, and 0.11 ± 0.73D for cycloplegic autorefractometer measurements, respectively. Cycloplegic autorefractometer values showed a significant hyperopic shift of 6.57 ± 1.26D and 6.67 ± 1.34D for spherical and spherical equivalents, respectively, compared to non-cycloplegic values (p < 0.001 for both). There was no significant difference between non-cycloplegic photoscreener and cycloplegic autorefractometer measurements for spherical, cylindrical, and spherical equivalents (p = 0.126, p = 0.078, and p = 0.053, respectively). There was agreement between the measurements in the Bland-Altman graph. Conclusion: There was consistency between non-cycloplegic photoscreener and cycloplegic autorefractometer measurements in patients with pseudomyopia due to accommodation spasm. Therefore, photoscreener measurements can be a fast, practical, cost-effective examination method for screening these patients without the need for cycloplegia.