The impact of transcatheter aortic valve implantation (Tavi) on serum apelin levels in patients with aortic valvular stenosis
Brazilian Journal of Cardiovascular Surgery, cilt.36, sa.3, ss.372-378, 2021 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 36 Sayı: 3
- Basım Tarihi: 2021
- Doi Numarası: 10.21470/1678-9741-2020-0208
- Dergi Adı: Brazilian Journal of Cardiovascular Surgery
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, EMBASE, MEDLINE, Directory of Open Access Journals
- Sayfa Sayıları: ss.372-378
- Anahtar Kelimeler: Apelin, Aortic Valve Stenosis, Transcatheter Aortic Valve Implantation, Aortic Valve Stenosis, Echocardiography
- Sağlık Bilimleri Üniversitesi Adresli: Evet
Özet
Introduction: In this study, we aimed to investigate the impact of transcatheter aortic valve implantation (TAVI) on serum apelin levels in patients with severe symptomatic aortic valve stenosis (AS). Methods: Forty-six consecutive patients (76.9±7.4 years, n=27 women) who underwent TAVI and 45 age-and sex-matched control subjects were included in the study. Echocardiographic parameters, serum apelin, pro-brain natriuretic peptide (Pro-BNP), and troponin I levels were compared between the groups. In addition, the preprocedural and first-month follow-up echocardiographic parameters and serum apelin values of TAVI patients were compared. Results: Serum median troponin I and Pro-BNP levels were significantly higher and serum apelin levels were significantly lower in TAVI patients before TAVI procedure than in the control subjects (P<0.001, for all). Median troponin I and Pro-BNP levels were significantly decreased and apelin levels were significantly increased after TAVI procedure compared to the peri-procedural levels. There was a significant and moderate negative correlation between Pro-BNP and apelin levels measured before and after TAVI procedure. A statistically significant and strong negative correlation was found between aortic valve area and Pro-BNP level before TAVI procedure, while a statistically significant but weak positive correlation was found between valve area and apelin level. Conclusion: In our study, apelin levels were significantly lower and Pro-BNP levels were higher in AS patients compared with the control group. Moreover, after TAVI procedure, a significant increase in apelin levels and a significant decrease in Pro-BNP levels were observed. There was also a negative and moderate correlation between apelin and Pro-BNP levels.