Transcatheter aortic valve implantation of the self-expanding Corevalve in a patient with bicuspid aortic stenosis: Case report


ASLAN S., Öztürk D., Çelik Ö., Gül M., Yildirim A.

Turkiye Klinikleri Cardiovascular Sciences, cilt.26, sa.2, ss.93-95, 2014 (Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 26 Sayı: 2
  • Basım Tarihi: 2014
  • Dergi Adı: Turkiye Klinikleri Cardiovascular Sciences
  • Derginin Tarandığı İndeksler: Scopus
  • Sayfa Sayıları: ss.93-95
  • Anahtar Kelimeler: Aortic valve stenosis, Bicuspid
  • Sağlık Bilimleri Üniversitesi Adresli: Evet

Özet

Transcatheter aortic valve implantation (TAVI) has emerged as an alternative to surgical aortic valve replacement for patients with symptomatic severe aortic stenosis considered to be at very high or prohibitive operative risk. Although bicuspid aortic valve is regarded as a relative contraindication to transcatheter aortic valve implantation several reports stated their TAVI experiences with bicuspid aortic valve. A 58-year old male patient presented with dyspne. Echocardiography demonstrated decreased left ventricular ejection fraction and severe calcified bicuspid aortic stenosis with valve area of 0.6 cm2 and mean transvalvular gradient of 45 mmHg. Aortic annulus diameter measured as 24 mm and ascending aorta 33 mm. He had very high surgical risk (Logistic EuroSCORE= 25.92% and STS score 15.6%). A 29 mm CoreValve device was successfully implanted percutaneously through the right femoral artery. In this case report, we present a patient with bicuspid aortic valveand symptomatic severe aortic stenosis treated successfully with TAVI.