Investigation of the color discrimination ability using the Farnsworth-Munsell 100-hue test and structural changes by SS-OCT in patients with transfusion-dependent beta-thalassemia
Photodiagnosis and Photodynamic Therapy, cilt.43, 2023 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 43
- Basım Tarihi: 2023
- Doi Numarası: 10.1016/j.pdpdt.2023.103716
- Dergi Adı: Photodiagnosis and Photodynamic Therapy
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, MEDLINE
- Anahtar Kelimeler: Beta-thalassemia, Color discrimination, Farnsworth Munsell 100-hue test, Swept-source, optical coherence tomography, Blood transfusion
- Sağlık Bilimleri Üniversitesi Adresli: Evet
Özet
Aim: This study aimed to examine the color discrimination ability of patients with transfusion-dependent beta-thalassemia (TDβ-T) in detail using the Farnsworth Munsell (FM) 100-hue test and to evaluate structural changes by swept source-optical coherence tomography (SS-OCT). Material and methods: This prospective, sectional study included 40 patients (79 eyes) with TDβ-T and 21 controls (42 eyes). The volunteers underwent a detailed ophthalmological examination and SS-OCT (DRI-OCT, Triton) imaging. Excluded were those with congenital color vision defects detected with the Ishihara pseudoisochromatic test. The patients’ color vision was examined using the FM 100-hue test. The total error score (TES), the blue-yellow local error score (b-y LES), and the red-green local error score (r-g LES) were calculated. p <0.05 was considered significant. Results: The mean age was 30.34±6.94 years in the patient group and 32.26±6.43 years in the control group (p = 0.078). The patient group had a significantly lower hemoglobin level (9.25±0.87 g/dL vs. 14±1.79 g/dL, p <0.001) and a significantly higher ferritin level (2665.56±2658.05 μg/L vs. 52.87±69.59 μg/L, p<0.001) compared to the control group. The mean TES, b-y LES, and r-g LES were higher in the patients than in the controls (64.84±30.18 vs. 28.45±16.55, p<0.001, 34.21±17.54 vs. 15.67±10.07, p <0.001, and 29.32±15.72 vs. 12.12±7.94, p<0.001, respectively). The patients had a higher b-y LES than r-g LES (34.21±17.54 vs. 29.32±15.72, p = 0.015). Choroidal thickness was lower in the patients than in the controls (284.34±63.55 µm vs. 324.98±88.05 µm, p = 0.043). Conclusion: We found that the color discrimination ability of the patients with TDβ-T was reduced in both the r-g and b-y color axes compared to the controls, and their color discrimination ability in the b-y color axis was more affected than in the r-g axis.