Left atrial mechanical functions in pre-eclampsia
Journal of Obstetrics and Gynaecology Research, cilt.31, sa.6, ss.535-539, 2005 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 31 Sayı: 6
- Basım Tarihi: 2005
- Doi Numarası: 10.1111/j.1447-0756.2005.00332.x
- Dergi Adı: Journal of Obstetrics and Gynaecology Research
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
- Sayfa Sayıları: ss.535-539
- Anahtar Kelimeler: echocardiography, left atrial function, pre-eclampsia
- Sağlık Bilimleri Üniversitesi Adresli: Evet
Özet
Aim: To assess the effect of short-term pressure overload on left atrial (LA) mechanical function in pre-eclampsia. Methods: Twenty women with pre-eclampsia and 17 age-matched healthy pregnant women were included. LA volumes were measured echocardiographically at the time of mitral valve opening (Vmax), onset of atrial systole (p-wave at the electrocardiography = Vp) and mitral valve closure (Vmin) according to the biplane area-length method. Results: The mean age, gestational age, weight and body surface area were similar in pre-eclampsia and controls. The ventricular septal and posterior wall thickness were greater in pre-eclampsia (P < 0.001). There were no significant differences in LA diameter, Vmax, Vmin, Vp, LA-passive emptying volume, LA-passive emptying fraction, LA-active emptying volume, LA-active emptying fraction, conduit volume, LA-total emptying volume and LA-total emptying fraction between the groups. Conclusion: Left atrial mechanical function didn't change in pre-eclampsia. We conclude that short-lasting pressure overload is not capable of inducing changes in LA function.