The value of whole-body contrast-enhanced 18 F-FDG PET/CT imaging in the diagnosis and staging of patients with laryngeal carcinoma


Tatar G., Cermik T. F., Karagoz Y., Gundogan C., Karacetin D., Yildiz E., ...Daha Fazla

Nuclear Medicine Communications, cilt.39, sa.4, ss.334-342, 2018 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 39 Sayı: 4
  • Basım Tarihi: 2018
  • Doi Numarası: 10.1097/mnm.0000000000000809
  • Dergi Adı: Nuclear Medicine Communications
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.334-342
  • Anahtar Kelimeler: contrast enhanced, 18F-FDG PET, CT, laryngeal carcinoma, tumor staging
  • Sağlık Bilimleri Üniversitesi Adresli: Evet

Özet

Purpose This study aimed to determine whether intravenous contrast-enhanced dual-phase fluorine-18-fluorodeoxyglucose (18 F-FDG) PET/CT scans provide additional diagnostic information compared with the MRI/CT in patients with laryngeal carcinoma during the initial staging. Patients and methods Forty-five consecutive patients (44 men, one woman; mean age±SD, 67.0±9.0 years, range: 45-80 years) with carcinoma of the larynx who had MRI/CT and intravenous contrast-enhanced PET/CT were enrolled. Each patient was scanned on the PET/CT system 1 h (early) and 2 h (delayed) after injection. The maximum standardized uptake values of the primary tumor, nodal, and distant metastatic lesions were measured using the dual-time-point method. Double-blinded 18 F-FDG PET/CT and MRI/CT staging data were compared. The diagnostic accuracy of each modality was compared for primary tumors, nodal metastasis, and the tumor staging. Results For primary tumor detection, the sensitivity of PET/CT was higher (100%) than MRI/CT (93.3%). The accuracy for N status was 88.8% for PET/CT, being superior to MRI, which had an accuracy of 66.6%. The sensitivity and specificity for the detection of nodal metastasis were 100 and 84.6% for PET/CT compared with 100 and 50% for MRI/CT, respectively. As an initial TNM-staging method, the PET/CT had a diagnostic accuracy of 86.6% compared with 44.4% for MRI/CT. Conclusion The results suggest that contrast-enhanced dual-phase PET/CT imaging contributes additional diagnostic information compared with the conventional methods for the initial evaluation of primary laryngeal tumors. 18 F-FDG PET/CT has a good diagnostic performance for the detection of regional nodal and distant metastasis, and also synchronous tumors in patients with laryngeal carcinoma.