Iatrogenic Arteriovenous Fistula between the Common Carotid Artery and Internal Jugular Vein: A Case Report


ERKUT B., Becit N., KAYĞIN M. A., VELİOĞLU Y.

EJVES Extra, cilt.10, sa.3, ss.74-76, 2005 (Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 10 Sayı: 3
  • Basım Tarihi: 2005
  • Doi Numarası: 10.1016/j.ejvsextra.2005.07.001
  • Dergi Adı: EJVES Extra
  • Derginin Tarandığı İndeksler: Scopus
  • Sayfa Sayıları: ss.74-76
  • Anahtar Kelimeler: Arteriovenous fistula, Central venous catheterization, Complications, Internal jugular vein
  • Sağlık Bilimleri Üniversitesi Adresli: Evet

Özet

Arteriovenous fistula is a rare complication of internal jugular vein catheterization. Few cases have been reported in the literature. This communications result from trauma or medical intervention, most frequently a central venous puncture for hemodynamic monitoring or for parenteral nutrition. We describe a case of a common carotid artery-jugular vein arteriovenous fistula following the insertion of a double-lumen catheter for hemodialysis access. We feel that this complication early should be detected and treated as soon as possible. © 2005 Elsevier Ltd. All rights reserved.