Transcatheter ventricular septal defect closure in children: ten-year experience with multiple devices and long-term outcomes
Egyptian Heart Journal, cilt.78, sa.1, 2026 (ESCI, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 78 Sayı: 1
- Basım Tarihi: 2026
- Doi Numarası: 10.1186/s43044-026-00753-4
- Dergi Adı: Egyptian Heart Journal
- Derginin Tarandığı İndeksler: Emerging Sources Citation Index (ESCI), Scopus, Arab World Research Source, EMBASE, Directory of Open Access Journals, Health Research Premium Collection (ProQuest)
- Anahtar Kelimeler: Complications, Long-term outcomes, Occluder devices, Transcatheter closure, Ventricular septal defect
- Sağlık Bilimleri Üniversitesi Adresli: Evet
Özet
Background: Transcatheter closure has become a widely accepted alternative to surgery for VSD, but long-term pediatric data are limited. This study evaluated procedural success, complications, and long-term outcomes with different occluders. Methods: We retrospectively analyzed 118 children who underwent attempted transcatheter VSD closure between 2014 and 2024, with clinical, echocardiographic, and electrocardiographic follow-up. Results: Closure was successful in 110 patients (93%). Failures were due to multifenestrated anatomy, embolization, residual shunt, atrioventricular (AV) block, tricuspid regurgitation, or insufficient aortic rim. Major complications occurred in six patients, including device embolization, progressive aortic regurgitation requiring surgery, persistent nodal rhythm requiring device removal, ventricular perforation, infective endocarditis, and subarachnoid hemorrhage. Minor complications included mild to moderate tricuspid regurgitation (n = 4) and mild aortic regurgitation (n = 5). Arrhythmic events comprised supraventricular tachycardia (n = 2, both resolved), nodal rhythm (n = 1, transient), right bundle branch block (n = 5, persistent in four), and left bundle branch block (n = 1, resolved). Residual shunt was present in 36.4% immediately, declining to 9.8% at follow-up. Larger VSD diameter (OR 1.75, 95% CI 1.14–2.69) and higher body weight (OR 1.07, 95% CI 1.00–1.15) were independent predictors. No late complete AV block, endocarditis, or embolization occurred. Patients treated with Konar-MF were younger and lighter, while Nit-Occlud was associated with higher residual shunt rates (85.7% vs. 33.0%, p = 0.010). Conclusion: Transcatheter VSD closure in children demonstrated high success, acceptable complication rates, and favorable long-term outcomes. Results were influenced by device choice, defect size, and patient characteristics, highlighting the need for individualized strategies and continued surveillance.