Successful embolisation of coronary artery fistulas with the Azur® CX peripheral coil system in three paediatric patients


Torun E. G., Pamuk U., Çayhan V., GÜRSU H. A.

Cardiology in the Young, cilt.35, sa.3, ss.645-648, 2025 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 35 Sayı: 3
  • Basım Tarihi: 2025
  • Doi Numarası: 10.1017/s1047951125000447
  • Dergi Adı: Cardiology in the Young
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, EMBASE, MEDLINE
  • Sayfa Sayıları: ss.645-648
  • Anahtar Kelimeler: coil embolisation, coronary artery fistula, transcatheter closure, Azur (R) CX Peripheral Coil, children
  • Sağlık Bilimleri Üniversitesi Adresli: Evet

Özet

Coronary artery fistulas are rare cardiac anomalies, often asymptomatic and frequently discovered incidentally during routine cardiac imaging. Transcatheter closure with coil embolisation is increasingly recognised as a preferable alternative to surgical intervention due to its lower complication rates. In this report, we present three paediatric cases in which coronary artery fistulas were successfully embolised using the Azur® CX Peripheral Coil System. This system demonstrates low-profile suitability for occluding highly tortuous vessels in children, enabling controlled coil delivery via a microcatheter. Its hydrogel-coated coils allow for expansion between gaps, making it highly effective as a minimally invasive treatment.