Changes of ocular biometry in eyes with posterior chamber phakic intraocular lens implantation Modifications de la biométrie oculaire dans les yeux avec implantation de lentille intraoculaire phaque de chambre postérieure


Kayhan B., Coskunseven E.

Journal Francais d'Ophtalmologie, cilt.45, sa.4, ss.377-383, 2022 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 45 Sayı: 4
  • Basım Tarihi: 2022
  • Doi Numarası: 10.1016/j.jfo.2021.10.006
  • Dergi Adı: Journal Francais d'Ophtalmologie
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, PASCAL, CAB Abstracts, EMBASE, MEDLINE, Veterinary Science Database
  • Sayfa Sayıları: ss.377-383
  • Anahtar Kelimeler: Anterior chamber depth, Axial length, Implantable cottamer lens, Intraocular lens calculation, Myopia, Ocular biometry, Phakic intraocular tens
  • Sağlık Bilimleri Üniversitesi Adresli: Hayır

Özet

Objective: To evaluate changes in biometric variables and intraocular lens (IOL) calculation results after posterior chamber phakic IOL (PCPIOL) implantation. Methods: This retrospective, observational study included 65 eyes of 38 patients who underwent PCPIOL (EVO Visian ICL) implantation for correction of myopia. Prior to and a minimum of one year (mean 14.9 months) after EVO Visian ICL implantation, biometric variables and IOL calculation results were compared. Optical biometry, including anterior chamber depth, axial length, flat, steep, and mean keratometry values and IOL calculation results for the Holladay 2, Hoffer Q, Haigis, and SRK/T formulas were measured using the IOLMaster 700 SWEPT Source OCT biometer. Main results: The mean anterior chamber depth decreased from 3.70 ± 0.22 mm to 3.34 ± 0.39 mm, the mean axial length increased from 26.61 ± 1.61 mm to 26.71 ± 1.66 mm, and the mean flat keratometry changed from 42.82 ± 1.86 D to 42.73 ± 1.83 D. These changes were statistically significant. The mean IOL power calculation also revealed a statistically significant decrease with all four formulas (ranging from 0.19 D to 0.30 D) after PCPIOL implantation. Conclusions: Biometric variables and IOL calculation results showed statistically significant changes one year after EVO Visian ICL implantations. However, IOL power calculations yielded a decrease of less than 0.50 D, inducing much less refractive deviation in the spectacle plane; and the change was primarily related to an increase in AL measurements. IOL power calculations in eyes with EVO Visian ICL in situ provided satisfactory and reliable results.