A NOVEL TRAINING ALTERNATIVE IN ORTHOGNATHIC MANDIBULAR OSTEOTOMY: AIR DRIED CLAY MODEL ORTOGNATİK MANDİBULA OSTEOTOMİSİNDE YENİ BİR EǦİTİM SEÇENEǦİ: HAVA KURUTMALI KİL MODELİ


Creative Commons License

Kozanoǧlu E., Akalin B. E., Berköz H. Ö., Karaali˙ S., Mammadova N., Ak E., ...Daha Fazla

Istanbul Tip Fakultesi Dergisi, cilt.84, sa.4, ss.482-487, 2021 (ESCI, Scopus, TRDizin)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 84 Sayı: 4
  • Basım Tarihi: 2021
  • Doi Numarası: 10.26650/iuitfd.2021.836789
  • Dergi Adı: Istanbul Tip Fakultesi Dergisi
  • Derginin Tarandığı İndeksler: Emerging Sources Citation Index (ESCI), Scopus, TR DİZİN (ULAKBİM)
  • Sayfa Sayıları: ss.482-487
  • Anahtar Kelimeler: Air-dried clay, mandible, model surgery, orthognathic surgery, training
  • Açık Arşiv Koleksiyonu: AVESİS Açık Erişim Koleksiyonu
  • Sağlık Bilimleri Üniversitesi Adresli: Evet

Özet

Objective: Patient safety and low complication rates are indispensable in surgical training and models are among the main educational tools. The aim of this study is to assess the efficiency of a novel model for orthognathic mandibular osteotomy. Material and Methods: A template and seventeen partial mandibular models (MM-17) were manufactured with air dried clay. The dimensions of the models were feasible for sagittal split ramus osteotomy (SSRO). Model surgery was performed by surgeons with a minimum of three years' experience in orthognathic surgery. Each surgeon operated four separate models and the following data were recorded: corticotomy and SSRO completion time, MM-17 fracture type, similarity value of MM-17 with native mandible, representation value of MM-17, and the training compatibility value of MM-17. Results: The cost was 0.6 American Dollars. The mean corticotomy time was 126.75 seconds (110-150). Mean cortical resistance similarity value was 8.75 (8-10). The mean SSRO time was 288 seconds (205-401). Sixty percent of the fractures were seen in the outer cortex. The mean medullary resistance similarity value was 5 (4-6) and mean mandibular representation value was 5.25 (4-7). The training compatibility value was 8.25 (7-10). Conclusion: Air dried clay demonstrated mechanical similarities with bone cortex and it was used for mandibular modelling for the first time. MM-17 cost less than other devices. Corticotomy and SSRO completion times were short due to the lack of dissection and bleeding. Despite its drawbacks in SSRO, MM- 17 is a versatile and low cost alternative in orthognathic mandibular corticotomy training. High power drill utilization skills may be gained with MM-17 before clinical practice.