Prognostic value of TAPSE/PASP ratio in right ventricular failure after left ventricular assist device implantation: Experience from a tertiary center Sol ventrikül destek cihaz implantasyonu sonrasında sağ kalp yetmezliğinde TAPSE/PASP oranının prognostik değeri
Turkish Journal of Thoracic and Cardiovascular Surgery, cilt.30, sa.3, ss.334-343, 2022 (SCI-Expanded, Scopus, TRDizin)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 30 Sayı: 3
- Basım Tarihi: 2022
- Doi Numarası: 10.5606/tgkdc.dergisi.2022.23218
- Dergi Adı: Turkish Journal of Thoracic and Cardiovascular Surgery
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, TR DİZİN (ULAKBİM)
- Sayfa Sayıları: ss.334-343
- Anahtar Kelimeler: Left ventricle assist device, pulmonary artery systolic pressure, right heart failure, tricuspid annular plane systolic excursion
- Sağlık Bilimleri Üniversitesi Adresli: Evet
Özet
Background: In this study, we aimed to investigate the prognostic value of the tricuspid annular plane systolic excursion (TAPSE)/ pulmonary arterial systolic pressure (PASP) ratio in right ventricular failure patients undergoing left ventricular assist device implantation. Methods: Between February 2013 and February 2020, a total of 75 heart failure patients (65 males, 10 females; median age: 54 years; range, 21 to 66 years) were retrospectively analyzed. The prognostic value of TAPSE/PASP ratio was assessed using the multivariate Cox regression models and confirmed using the Kaplan-Meier analyses. Results: Forty-one (55.4%) patients had an ischemic heart failure etiology. The indication for assist device implantation was bridge to transplant in 64 (85.3%) patients. The overall survival rates at one, three, and five years following left ventricular assist device implantation were 82.7%, 68%, and 49.3%, respectively. Right ventricular failure was observed in 24 (32%) patients during follow-up. In the multivariate analysis, TAPSE/PASP was found to be independently associated with postoperative right ventricular failure (HR: 1.63; 95% CI: 1.49-2.23). A TAPSE/PASP of 0.34 mm/mmHg was found to be the most accurate predictor value, with lower ratios correlating with right ventricular failure. The Kaplan-Meier analysis showed a better overall survival using a TAPSE/PASP ≥ of 0.34 mm/mmHg (p<0.001). Conclusion: A lower TAPSE/PASP ratio, particularly lower values than 0.34 mm/mmHg, strongly predicts right ventricular failure after left ventricular assist device implantation in patients with advanced heart failure.