Changes in corneal high order aberrations and anterior chamber parameters following scleral fixated intraocular lens implantation


TELLİOĞLU A., Beşek N. K., KIRGIZ A., Yılmaz F. Ö., Şimşek M., Ahmet S., ...Daha Fazla

Photodiagnosis and Photodynamic Therapy, cilt.42, 2023 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 42
  • Basım Tarihi: 2023
  • Doi Numarası: 10.1016/j.pdpdt.2023.103595
  • Dergi Adı: Photodiagnosis and Photodynamic Therapy
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, MEDLINE
  • Anahtar Kelimeler: Anterior chamber parameters aphakia, Cornea, Corneal wavefront aberration, Intraocular lenses
  • Sağlık Bilimleri Üniversitesi Adresli: Evet

Özet

Background: To evaluate the change in corneal high order aberrations (HOAs) and anterior chamber parameters following scleral fixation in aphakic patients using the Scheimpflug camera system. Methods: This retrospective study included patients who were aphakic after phacoemulsification surgery and underwent scleral-fixed intraocular lens (SF-IOL) implantation with Z suture technique between 2010 and 2022. Preoperative and postoperative best corrected visual acuity (BCVA), anterior segment parameters and corneal aberrations were evaluated with a combined Scheimpflug-Placido disk corneal topography device (Sirius Costruzione Strumenti Oftalmici, Florence, Italy). The following values were recorded: Simulated keratometry (SimK), flat meridian (K1), steep meridian (K2), iridocorneal angle (ICA), temporal anterior chamber angle (T-ACA), nasal anterior chamber angle (N-ACA), horizontal anterior chamber diameter (HACD), anterior chamber volume (ACV), corneal volume (CV), total Root Mean Square (RMS), high order aberrations (HOAs), spherical aberration, coma, trefoil, quadrifoil, and secondary astigmatism. Results: The study included 31 eyes of 31 patients (mean age: 63.00 ± 19.41 years, 17 males/14 females). Postoperative BCVA was better than preoperative BCVA (p = 0.012). Postoperatively, there was a statistically significant increase in ACV and CV values and a statistically significant decrease in K2 (p = 0.009, p = 0.032, p = 0.015). Preoperative T-ACA and preoperative and postoperative ACV were negatively correlated with postoperative intraocular pressure (r=-0.427 p = 0.033, r=-0.406 p = 0.032 and r=-0.561 p = 0.001). There were statistically significant postoperative increases in corneal RMS, trefoil and HOAs for 3 mm pupil diameter (p = 0.0177, p = 0.001, p = 0.031) and in corneal RMS, trefoil and quadrifoil aberrations for 6 mm pupil diameter (p = 0.033, p = 0.001, p = 0.001). Conclusions: In conclusion, SF-IOL implantation with Z-suture technique used for visual rehabilitation of aphakic patients may affect visual quality by increasing corneal HOAs while improving visual acuity.