Simplified calculation of mechanical power for pressure controlled ventilation in Covid-19 ARDS patients


Aşar S., Acicbe O., Sabaz M. S., Kucur Tülübaş E., Hergünsel G. O., Çukurova Z., ...Daha Fazla

Minerva Anestesiologica, cilt.88, sa.1-2, ss.42-50, 2022 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 88 Sayı: 1-2
  • Basım Tarihi: 2022
  • Doi Numarası: 10.23736/s0375-9393.21.15741-4
  • Dergi Adı: Minerva Anestesiologica
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, EMBASE, MEDLINE
  • Sayfa Sayıları: ss.42-50
  • Anahtar Kelimeler: Respiratory distress syndrome, Ventilator-induced lung injury, COVID-19
  • Sağlık Bilimleri Üniversitesi Adresli: Evet

Özet

BACKGROUND: Mechanical power (MP) is a promising tool for guidance of lung protective ventilation. Different equations have been proposed to calculate MP in pressure control ventilation (PCV). The aim of this study is to introduce an easy to use MP equation MPpcv(m-simpl) and compare it to an equation proposed by Van der Meijden et al. (MPpcv) which considered as the reference equation in PCV. METHODS: Ventilatory parameters of 206 Covid-19 ARDS patients recorded between 24-72 hours after admission to intensive care unit. The PCV data from these patients were retrospectively investigated. MP in PCV was calculated with a modified equation (MPpcv(m-simpl)) derived from the equation (MPpcv) of Van der Meijden etal.: 0.098xRRx∆Vx(PEEP+∆Pinsp - 1). The results from MPpcv(slope), MPpcv(simpl), and MPpcv(m-simpl) were compared to MPpcv at 15 cmH2O ∙ s/L inspiratory resistance levels by univariable regression and Bland-Altman analysis. RESULTS: Inspiratory resistance levels at 15 cmH2O s/L was found to be correlated between the power values calculated by MPpcv(simpl)/MPpcv(m-simpl) and the MPpcv(slope)/MPpcv based on univariable logistic regression (R2≥98) analyses. In the comparison of all patients average MP values computed by the MPpcv(m-simpl) equation and the MPpcv reference equation. Bland-Altman analysis mean difference and p values at 15 cmH2O s/L inspiratory resistance values (J/min) were found to be MPpcv(m-simpl) vs MPpcv=-0,04 (P=0.014); MPpcv(slope) vs. MPpcv=0.63 (P<0.0001); MPpcv(simpl) vs. MPpcv=0.64 J/min (P<0.0001), respectively. CONCLUSIONS: The results of this study confirmed that the MPpcv(m-simpl) equation can be used easily to calculate MP at bedside in pressure control ventilated COVID-19 ARDS patients.