Diagnostic accuracy of different imaging modalities in detection of proximal caries


ŞENEL B., KAMBUROĞLU K., Üçok Ö., YÜKSEL S., Özen T., Avsever H.

Dentomaxillofacial Radiology, cilt.39, sa.8, ss.501-511, 2010 (SCI-Expanded, Scopus)

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 39 Sayı: 8
  • Basım Tarihi: 2010
  • Doi Numarası: 10.1259/dmfr/28628723
  • Dergi Adı: Dentomaxillofacial Radiology
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.501-511
  • Anahtar Kelimeler: detection, cone beam computed tomography, digital radiography, film, proximal caries
  • Sağlık Bilimleri Üniversitesi Adresli: Evet

Özet

Objective: The purpose of this study was to assess the in vitro diagnostic ability of visual inspection, film, charge-coupled device (CCD) sensor, photostimulable phosphor (PSP) sensor and cone beam CT in the detection of proximal caries in posterior teeth compared with the histological gold standard. Methods: Visual inspection, film, CCD, PSP and cone beam CT images were used to detect proximal caries in the mesial and distal surfaces of 138 teeth (276 surfaces). Visual inspection and evaluation of all intraoral digital and conventional radiographs and cone beam CT images were performed twice by three oral radiologists. Weighted kappa coefficients were calculated to assess intra- and interobserver agreement for each image set, and scores were compared with the histological gold standard using receiver operating characteristic (ROC) analysis to evaluate diagnostic ability. Results: Intraobserver kappa coefficients calculated for each observer for each method of detecting caries ranged from 0.739 to 0.928. Strong interobserver agreement ranging from 0.631 to 0.811 was found for all detection methods. The highest Az values for all three observers were obtained with the cone beam CT images; however, differences between detection methods were not statistically significant (P > 0.05). Conclusion: Visual inspection, film, CCD, PSP plates and cone beam CT performed similarly in the detection of proximal caries. Copyright © 2010 The British Institute of Radiology.